Order in the next 23 hrs 22 mins
for next working day dispatch
Quality Products We Believe In
20+ Years Of Experience And Advice
Colour Matching Available
Stock Available For Immediate Dispatch

Jotun Steelmaster 600WF is a water-based intumescent paint providing sup to 90 minutes of fire protection for structural steel. It offers fast drying, low VOC emissions, and easy application, making it ideal for commercial and industrial projects. Compared to similar products, it stands out for its eco-friendly formulation, efficient fire resistance, and long-term durability, ensuring optimal safety with minimal environmental impact.

Given the nature of the product and its purpose it is important that all Steelmaster products are applied correctly.  If you require guidance on Steelmaster application for your project please contact us prior to placing your order.

Available from SML Paints in 5L and 18.5L tin sizes

  • Single pack intumescent paint
  • Water based
  • Up to 90 minutes fire protection
  • Excellent surface adhesion
  • Environmentally compliant - low VOC's
  • Lower film thickness requirement
  • Reduced application time
  • Mild and galvanised steel structures
  • Commercial buildings and industrial facilities
Jotun

Steelmaster 600WF

Jotun Steelmaster 600WF is a water-based intumescent paint providing sup to 90 minutes of fire protection for structural steel. It offers fast drying, low VOC emissions, and easy application, making it ideal for commercial and industrial projects. Compared to similar products, it stands out for its eco-friendly formulation, efficient fire resistance, and long-term durability, ensuring optimal safety with minimal environmental impact.

Given the nature of the product and its purpose it is important that all Steelmaster products are applied correctly.  If you require guidance on Steelmaster application for your project please contact us prior to placing your order.

Available from SML Paints in 5L and 18.5L tin sizes

  • Single pack intumescent paint
  • Water based
  • Up to 90 minutes fire protection
  • Excellent surface adhesion
  • Environmentally compliant - low VOC's
  • Lower film thickness requirement
  • Reduced application time
  • Mild and galvanised steel structures
  • Commercial buildings and industrial facilities
Fast Despatch and Delivery
Card Payments
From £65.95 excl. VAT £79.14 incl. VAT

Select an Option Below

Fast Despatch and Delivery
Card Payments

Jotun Steelmaster 600WF Overview

Jotun SteelMaster 600WF is a single component waterborne, thin-film intumescent coating engineered to provide up to 90 minutes of protection for structural steel exposed to fire. Its advanced formulation ensures efficient application with reduced coating thickness, making it a cost-effective solution for safeguarding steel structures. Compliant with environmental standards, SteelMaster 600WF boasts low volatile organic compound (VOC) content, aligning with sustainable building practices.

Key Product Features

  • Efficient Fire Protection - Offers up to 90 minutes of fire resistance for structural steel.
  • Low VOC Content - Environmentally friendly with reduced VOC emissions.
  • Reduced Film Thickness - Achieves required fire protection with thinner application layers.
  • Application Versatility - Suitable for airless spray, brush, or roller methods.
  • Global Approval - Meets international fire protection standards.  Steelmaster 600WF passed all relevant tests and approvals by Certifire, an independent third party certification scheme internationally recognised for ensuring the quality, performance, durability and traceability of fire protection products.

Suitable Uses and Applications

Jotun Steelmaster 600WF is suitable for carbon steel structure such as;

  • Commercial Buildings - Ideal for protecting structural steel in offices, retail locations and educational institutions.
  • Industrial Facilities - Suitable for factories, warehouses, and power plants requiring fire protection.
  • Public Infrastructure - Applicable in airports, train stations, and other public structures.

Basic Application Guide for Jotun Steelmaster 600WF

Given the nature of the product and its purpose it is important that all applications of Steelmaster products are performed correctly.  If you require guidance on Steelmaster application for your project please contact us prior to placing your order.

For more information on applying Jotun Steelmaster 600WF please see our detailed application guide here

Step 1 - Surface Preparation

  • Ensure all steel surfaces are clean, dry, and free from contaminants.
  • Apply an approved primer compatible with SteelMaster 600WF.

Step 2 - Mixing

  • Stir the product thoroughly to achieve a uniform consistency.

Step 3 - Application

  • Environmental Conditions - Maintain substrate and ambient temperatures between 10°C and 35°C.
  • Methods - Airless Spray is recommended for optimal finish and efficiency, whilst a brush or roller is suitable for touch-ups or small areas.
  • Coats - Apply as per the specified dry film thickness (DFT) to achieve desired fire protection.

Step 4 - Drying and Curing

  • Touch Dry - Approximately 1 hour at 23°C.
  • Overcoating Interval - Minimum 6 hours at 23°C.

Jotun Steelmaster 600WF Frequently Asked Questions (FAQ’s)

The FAQ's below are for general guidance only.  For specific questions, please refer to the application guides and data sheets on our product pages or give us call and we will answer any questions that you have.

Q. What is the primary function of SteelMaster 600WF?

A. SteelMaster 600WF provides up to 60 minutes of fire protection for structural steel exposed to cellulosic fires, enhancing building safety.

Q. Is SteelMaster 600WF environmentally friendly?

A. Yes, it is a waterborne coating with low VOC content, aligning with sustainable building practices.

Q. Can SteelMaster 600WF be applied over any primer?

A. It should be applied over Jotun-approved primers to ensure compatibility and optimal performance. 

Q. What application methods are suitable for SteelMaster 600WF?

A. It can be applied using airless spray, brush, or roller, with airless spray being the most efficient method.

Q. How should the surface be prepared before application?

A. Surfaces must be clean, dry, and free from contaminants, with an appropriate primer applied beforehand.

Q. What is the recommended storage condition for SteelMaster 600WF?

A. Store in a dry, cool, well-ventilated area away from heat sources, with containers tightly closed.

Q. Can SteelMaster 600WF be used in exterior environments?

A. It is primarily designed for interior use.  If used outdoors, it must be immediately top-coated with a weather-resistant product such as Hardtop XP.

Q. What is the shelf life of SteelMaster 600WF?

A. When stored properly, it has a shelf life of up to 6 months at 23°C.

Q. Is thinning required before application?

A. Thinning is not typically necessary; use as supplied after thorough stirring.

Q. How is the required dry film thickness (DFT) determined?

A. DFT is specified based on the desired fire protection duration and structural requirements; refer to project specifications.  Contact us and we will calculate the film thickness of paint necessary to meet your specification.  There is no charge for this service.

Q. Can SteelMaster 600WF be top-coated for aesthetic purposes?

A. Yes, it can be overcoated with compatible topcoats such as Conseal Touch-Up for colour and additional protection.

Q. What environmental conditions are ideal during application?

A. Apply when substrate and ambient temperatures are between 10°C and 35°C, with relative humidity below 85%.

Q. How long does it take for SteelMaster 600WF to fully cure?

A. Full curing typically occurs within 7 days at 23°C. However, curing times may vary depending on temperature, humidity, and ventilation. Lower temperatures can extend the curing process.

Q.  What is the minimum dry film thickness (DFT) required for 60-minute fire protection?

A. The required DFT depends on the steel section size and fire rating requirements. The specific thickness should be determined based on project specifications and fire test certifications.

Q.  Can SteelMaster 600WF be applied to galvanized steel?

A. Yes, but the galvanized surface must be properly prepared by degreasing and lightly abrading to ensure good adhesion. A suitable primer, such as Jotun Barrier or Jotacote Universal, should be applied before SteelMaster 600WF.

Q. Does SteelMaster 600WF have an expiry date?

A. Yes, when stored correctly in sealed containers at temperatures between 5°C and 35°C, SteelMaster 600WF has a shelf life of approximately 6 months from the manufacturing date.

Q. How should application tools be cleaned after using SteelMaster 600WF?

A. Since it is a waterborne product, tools and equipment should be cleaned immediately after use with warm water and detergent. Dried paint may require mechanical removal.

Q. What are the advantages of SteelMaster 600WF over solvent-based intumescent coatings?

A. SteelMaster 600WF offers lower VOC emissions, faster drying times, and easier cleanup with water, making it more environmentally friendly. It also allows for reduced film thickness, improving efficiency without compromising fire protection performance.

Feature Details
Brand Jotun
Paint Protection Intumescent
Paint Type Universal Coating
Paint Components Single Pack
Ease of Use 4. Fair
Substrate Suitability Mild Steel, Galvanised Steel
Surface Adhesion 1. Excellent
Above / Below Waterline Above Water
Water Resistance 5. Limited
Chemical Resistance 5. Limited
Interior / Exterior Use Interior
Flexibility 5. Limited
Application Method Airless Spray, Roller, Brush
Chemical Composition Water Based
Brand Range Steelmaster
Brush or Roller Coverage Rate (m2 / L) 8
Cured for Service 10C (days) 1
Cured for Service 23C (days) 1
Dry to Overcoat 10C (hours) 16
Dry to Overcoat 23C (hours) 6
Full Curing Time 10C (days) 1
Full Curing Time 23C (days) 1
Max Dry Film Thickness per Coat (microns) 710
Max Overcoating Time without Sanding (days) Extended
Min Dry Film Thickness per Coat (microns) 140
Product Type Paint
Self-Priming No